Copyright 2008 Ersan Ismaili , CF PROGRESI
CATALOG
![]()
PVC INSULATED SINGLE CORE CABLE
H05V-U (P)
DIN VDE 0281
HD 21.3S3
IEC 60 502-1
NOMINAL VOLTAGE: 1000 V
TESTING VOLTAGE: 2000 V
Description: Untinned solid copper conductor insulated with extruded PVC tube.
Standard Color: Green/yellow, light-blue, black-brown.
Application:
In dry locations, for permanent laying in tubes which may be
installed overor under the mortar, as well as on insulators.
The maximum permissible temperature is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
H05V - U 1x1.5 |
0.6 |
2.7 |
14.4 |
H05V - U 1x2.5 |
0.7 |
3.3 |
24 |
H05V - U 1x4 |
0.8 |
4.0 |
38 |
H05V - U 1x6 |
0.8 |
4.5 |
58 |
H05V - U 1x10 |
1.0 |
5.7 |
96 |
![]()
SPECIAL PVC INSULATED SINGLE CORE CABLE
P/J
IEC 60 502-1 ( JUS.N.C3.203 )
NOMINAL VOLTAGE : 1000 V
TESTING VOLTAGE: 3000 V
Description: Untinned copper conductor insulated with reinforced extruded PVC tube.
Standard Color: Green/yellow, light-blue, black-brown.
Application: In damp locations, and outdoors, on insulators
(for house installations), as well as for the wiring in the machine
tools and ships with an appropriate protection.
The maximum permissible temperature is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
P/J 1x1 |
0.8 |
2.9 |
9.6 |
P/J 1x1.5 |
1.0 |
3.6 |
14.4 |
P/J 1x2.5 |
1.0 |
4.0 |
24 |
P/J 1x4 |
1.0 |
4.5 |
38 |
P/J 1x6 |
1.0 |
5.0 |
58 |
![]()
FLEXIBILE PVC INSULATED SINGLE CORE CABLE
H05V-K (P/F)
DIN VDE 0281
HD 21.3S3
IEC 60 502-1
NOMINAL VOLTAGE: 1000 V
TESTING VOLTAGE: 2500 V
Description: Untinned soft annealed stranded copper
wire conductor insulated with extruded PVC tube.
Standard Colors: Green/yellow, light-blue, black-brown.
Application: In dry locations, and in the locations where a particular flexibility is required.
For building installations where the cables are laid in tubes which may be installed
over or under the mortar, as well as for installation on insulators.
The cables having the cross-section of 0,5 and 0,75 mm² are used for installation on electric
appliances.
The maximum permissible temperature is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
H05V - K 1x0.5 |
0.6 |
2 |
4.8 |
H05V - K 1x0.75 |
0.6 |
2.2 |
7.2 |
H05V - K 1x1 |
0.6 |
2.6 |
9.6 |
H05V - K 1x1.5 |
0.6 |
2.9 |
14.4 |
H05V - K 1x2.5 |
0.7 |
3.5 |
24 |
H05V - K 1x4 |
0.8 |
4.3 |
38 |
H05V - K 1x6 |
0.8 |
5.3 |
58 |
H05V - K 1x10 |
1.0 |
6.8 |
96 |
H05V - K 1x16 |
1.0 |
8.2 |
154 |
![]()
PVC INSULATED AND SHEATHED FLAT CABLE
NYIFY (PP/R)
DIN VDE 0250
IEC 60 502-1
NOMINAL VOLTAGE: 380 V
TESTING VOLTAGE: 2000 V
Description: Untinned copper conductor insulated with a seamless layer of PVC compound.
The cores are parallel, and over them a common PVC sheath is extruded,
so that between the cores there is a path providing for a provisory fixing of the cord.
Standard Color: Black
Application: For power supply installations, in dry locations,
for permanent laying in or under the mortar without any specific protection.
The maximum permissible temperature is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
NYIFY 2x1.5 |
0.6 |
9.2 |
29 |
NYIFY 2x2.5 |
0.7 |
10.5 |
48 |
NYIFY 2x4 |
0.8 |
11.9 |
76 |
NYIFY 3x1.5 |
0.6 |
9.7 |
43 |
NYIFY 3x2.5 |
0.7 |
11.0 |
72 |
NYIFY 3x4 |
0.8 |
12.5 |
115 |
![]()
PVC INSULATED AND SHEATHED CABLE
NYM- J (PP/Y)
DIN VDE 0250-204
IEC 60 502-1
NOMINAL VOLTAGE: 500 V
TESTING VOLTAGE: 2000 V
Description: Untinned copper conductor insulated with a seamless layer of PVC compound.
Two or more wires stranded together. The interstices are filled with unvulcanized rubber
or a similar material and over the filler there is extruded PVC sheath.
Standard Color: Grey
Application: In dry and damp locations, for laying in, over and under the mortar,
as well as outdoors.
The maximum permissible temperature is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
NYM - J 2x1.5 |
0.6 |
9.2 |
29 |
NYM - J 2x2.5 |
0.7 |
10.5 |
48 |
NYM - J 2x4 |
0.8 |
11.9 |
76 |
NYM - J 2x6 |
0.8 |
12.9 |
115 |
NYM - J 3x1.5 |
0.6 |
9.7 |
43 |
NYM - J 3x2.5 |
0.7 |
11.0 |
72 |
NYM - J 3x4 |
0.8 |
12.5 |
115 |
NYM - J 3x6 |
0.8 |
14.1 |
173 |
NYM - J 4x1.5 |
0.6 |
10.4 |
58 |
NYM - J 4x2.5 |
0.7 |
11.9 |
96 |
NYM - J 4x4 |
0.8 |
14.0 |
154 |
NYM - J 4x6 |
0.8 |
15.2 |
230 |
NYM - J 4x10 |
1.0 |
18.7 |
384 |
NYM - J 5x1.5 |
0.6 |
11.2 |
72 |
NYM - J 5x2.5 |
0.7 |
12.8 |
120 |
NYM - J 5x4 |
0.8 |
15.1 |
192 |
NYM - J 5x6 |
0.8 |
16.5 |
288 |
NYM - J 5x10 |
1.0 |
20.3 |
480 |
MEDIUM PVC INSULATED AND SHEATHED CABLE
H05VV-F (PP/J)
DIN VDE 0281, HD 21.5 S3
IEC 60 502-1
NOMINAL VOLTAGE: 380 V
TESTING VOLTAGE: 2000 V
Description: Untinned soft annealed stranded copper wire conductor insulated with extruded
PVC tube. Two or more cores are twisted together and protected
with a sheath of PVC compound.
Standard Color: Black and white.
Application: For connecting the portable electric appliances operating under unfavorable
conditions where the cord cannot be in contact with the surfaces heated up to a temp.
above 85°C
The max. permissible temp. is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
H05VV - F 2x0.75 |
0.6 |
6.6 |
14.4 |
H05VV - F 2x1.0 |
0.6 |
7.0 |
19.2 |
H05VV - F 2x1.5 |
0.6 |
7.5 |
29 |
H05VV - F 2x2.5 |
0.7 |
9.3 |
48 |
H05VV - F 3x0.75 |
0.6 |
7.0 |
21.6 |
H05VV - F 3x1.0 |
0.6 |
7.4 |
29 |
H05VV - F 3x1.5 |
0.6 |
8.0 |
43 |
H05VV - F 3x2.5 |
0.7 |
9.9 |
72 |
H05VV - F 3x4 |
0.8 |
12.0 |
115 |
H05VV - F 3x6 |
0.8 |
13.0 |
172 |
H05VV - F 4x0.75 |
0.6 |
7.7 |
29 |
H05VV - F 4x1.0 |
0.6 |
8.1 |
38 |
H05VV - F 4x1.5 |
0.6 |
9.2 |
58 |
H05VV - F 4x2.5 |
0.7 |
11.2 |
96 |
H05VV - F 4x4 |
0.8 |
13.0 |
154 |
H05VV - F 4x6 |
0.8 |
15.1 |
230 |
H05VV - F 5x0.75 |
0.6 |
8.3 |
36 |
H05VV - F 5x1.0 |
0.6 |
8.8 |
48 |
H05VV - F 5x1.5 |
0.6 |
9.3 |
72 |
H05VV - F 5x2.5 |
0.7 |
12.4 |
120 |
H05VV - F 5x4 |
0.8 |
14.5 |
192 |
H05VV - F 5x6 |
0.8 |
16.1 |
288 |
PVC INSULATED AND SHEATED POWER CABLE
NYY and NAYY (PPOO-Y and PPOO-A)
DIN VDE 0276, HD 663.1
IEC 60 502-1
TENSIONI NOMINAL : 0.6/1 kV
Description: Conductor Soft annealed solid or stranded copper or aluminum wire.
Insulation: A seamless layer of PVC compound.
Cable Core: Stranded cores covered with unvulcanized rubber layer.
The cables with the shaped conductors have the layer made of thermoplastic tapes.
Sheath: Black extruded PVC tube.
Standard Color: Black
Application: For power distribution in city networks, industrial plants,
thermo-power and hydro-power stations. They are laid in cable trenches, indoors,
in the ground when having the additional protection.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. Diam. |
Cooper weigh |
Aluminium weight |
mm² |
mm |
mm |
kg/km |
kg/km |
1x10 |
1.0 |
10.0 |
89 |
27 |
1x16 |
1.0 |
11.5 |
144 |
43 |
1x25 |
1.2 |
13.0 |
228 |
69 |
1x35 |
1.2 |
14.0 |
316 |
96 |
2x1.5 |
0.8 |
12.5 |
27 |
|
2x2.5 |
0.8 |
13.0 |
45 |
|
2x4 |
1.0 |
15.0 |
72 |
22 |
2x6 |
1.0 |
16.0 |
109 |
33 |
2x10 |
1.0 |
16.0 |
182 |
55 |
3x1.5 |
0.8 |
13.0 |
41 |
|
3x2.5 |
0.8 |
14.0 |
68 |
|
3x4 |
1.0 |
16.0 |
108 |
33 |
3x6 |
1.0 |
16.5 |
163 |
49 |
3x10 |
1.0 |
18.0 |
272 |
83 |
4x1.5 |
0.8 |
13.5 |
54 |
|
4x2.5 |
0.8 |
14.5 |
90 |
|
4x4 |
1.0 |
17.0 |
144 |
44 |
4x6 |
1.0 |
18.0 |
217 |
66 |
4x10 |
1.0 |
20.0 |
363 |
110 |
4x25 |
1.2 |
28.5 |
932 |
178 |
4x35 |
1.2 |
31.0 |
1292 |
282 |
5x1.5 |
0.8 |
14.5 |
68 |
392 |
5x2.5 |
0.8 |
15.5 |
113 |
|
5x4 |
1.0 |
18.0 |
180 |
|
5x6 |
1.0 |
19.5 |
271 |
|
5x10 |
1.0 |
22.4 |
470 |
|
5x16 |
1.2 |
24.5 |
744 |
|
LIGHT PVC INSULATED AND SHEATHED FLEXIBLE CABLE
H03VV-F (PP/L)
DIN VDE 0281
IEC 60 227.5
NOMINAL VOLTAGE: 380 V
TESTING VOLTAGE: 2000 V
Description: Untinned soft annealed stranded copper wire conductor insulated with extruded
PVC tube.
Standard Color: Black and white.
Application: In dry location for connecting the smaller portable electric appliances with
operate under favorable conditions , such as portable lamps, fans, refrigerators and household
heating appliances where the cord cannot be in contact with the surfaces heated up to a temp.
above 85°C
The max. permissible temp. is 70°C.
No. conductors x cross sec. |
Thickness of Insulation |
Overall diam. |
Cooper weight |
mm² |
mm |
mm |
kg/km |
H03VV - F 2x0.75 |
0.5 |
5.8 |
14 |
H03VV - F 2x1.0 |
0.5 |
6.1 |
18.5 |
H03VV - F 3x0.75 |
0.5 |
6.1 |
21 |
H03VV - F 3x1.0 |
0.5 |
6.5 |
28 |
H03VV - F 4x0.75 |
0.5 |
6.7 |
28 |
H03VV - F 4x1.0 |
0.5 |
7.1 |
37.5 |